{"id":1130,"date":"2016-06-20T15:53:12","date_gmt":"2016-06-20T13:53:12","guid":{"rendered":"http:\/\/gino.xtek.hosting\/?page_id=1130"},"modified":"2022-01-20T18:22:35","modified_gmt":"2022-01-20T17:22:35","slug":"starting-resistors","status":"publish","type":"page","link":"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/","title":{"rendered":"Starting resistors"},"content":{"rendered":"<div id=\"pl-1130\"  class=\"panel-layout\" ><div id=\"pg-1130-0\"  class=\"panel-grid panel-has-style\" ><div class=\"sidebar-row panel-row-style panel-row-style-for-1130-0\" ><div id=\"pgc-1130-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-1130-0-0-0\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-first-child\" data-index=\"0\" ><div class=\"textwidget\"><p>Starting resistors are used to start large three-phase asynchronous machines with slip-ring rotor. The starting resistor is started in the rotor circuit and switched off stepwise. It limits the starting current of the motor and increases its effective component (rating factor) and thus the drive torque because only the effective component is decisive for the motor torque.<\/p>\n<p>The resistor and its stepping determine the starting performance of the drive. Stepping is designed either such that the same peak starting current I2 flows from step to step or (ideally) that the motor has a defined starting performance. The ratio 1 \/ I2 (I1 = current at which the next step is switched) indicates by how much the next step is smaller than the previous one and determines the number of starting steps.<\/p>\n<p>Formerly, the starting steps were switched by way of manually or motor-actuated drum starters or cam-operated switches with a specified switching sequence. Today, mainly contactors are used for this task, which are switched as a function of time, current or rotor speed.<\/p>\n<p>While smaller drives mostly require resistors with a defined stepping, larger motors are operated with dually stepped resistors to limit the number of rotor contactors. 5 or 6 rotor contactors give 2<sup>5<\/sup>\u00a0- 1 bzw. 2<sup>6<\/sup>\u00a0\u20131 steps, respectively, that are selected according to the desired starting performance and controlled with adequate software.<br \/>\n\u00a0<\/p>\n<\/div><\/div><div id=\"panel-1130-0-0-1\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-last-child\" data-index=\"1\" ><div class=\"product-text panel-widget-style panel-widget-style-for-1130-0-0-1\" ><div class=\"textwidget\"><h2>Products:<\/h2>\n<p class=\"produktlink\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/oil-cooled-resistor-starters\/\">Oil-cooled resistor starters \u00bb<\/a><\/p>\n<p class=\"produktlink\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/liquid-cooled-starters\/\">Liquid-cooled starters \u00bb<\/a><\/p>\n<p class=\"produktlink\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/motor-starters\/\">Motor starters \u00bb<\/a><\/p>\n<\/div><\/div><\/div><\/div><div id=\"pgc-1130-0-1\"  class=\"panel-grid-cell\" ><div id=\"panel-1130-0-1-0\" class=\"so-panel widget widget_nav_menu panel-first-child\" data-index=\"2\" ><div class=\"sidebar panel-widget-style panel-widget-style-for-1130-0-1-0\" ><div class=\"menu-submenu-products-en-container\"><ul id=\"menu-submenu-products-en\" class=\"menu\"><li id=\"menu-item-8018\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8018\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/resistance-systems-gino-ag\/\" title=\"Resistor systems\"><i>Overview Resistor systems<\/i><\/a><\/li>\n<li id=\"menu-item-8010\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-has-children menu-item-8010\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/load-and-test-resistors\/\">Load and test resistors<\/a>\n<ul class=\"sub-menu\">\n\t<li id=\"menu-item-8014\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8014\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/load-and-test-resistors\/standard-power-banks\/\">Standard load banks<\/a><\/li>\n\t<li id=\"menu-item-8011\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8011\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/load-and-test-resistors\/customer-specific-load-banks\/\">Customer specific load banks<\/a><\/li>\n\t<li id=\"menu-item-8013\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8013\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/load-and-test-resistors\/mobile-load-banks-on-trailers\/\">Mobile load banks on trailers<\/a><\/li>\n\t<li id=\"menu-item-8015\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8015\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/load-and-test-resistors\/test-resistors\/\">Test resistors<\/a><\/li>\n\t<li id=\"menu-item-8012\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8012\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/load-and-test-resistors\/load-banks-for-locomotives\/\">Load banks for locomotives<\/a><\/li>\n<\/ul>\n<\/li>\n<li id=\"menu-item-7998\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-7998\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/brake-resistors\/\">Braking resistors<\/a><\/li>\n<li id=\"menu-item-8008\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8008\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/grounding-resistors-gino-ag\/\">Earthing resistors<\/a><\/li>\n<li id=\"menu-item-8004\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8004\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/damping-resistors\/\">Damping resistors<\/a><\/li>\n<li id=\"menu-item-8019\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8019\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/transportation-engineering-train-resistors\/\">Transportation engineering \/ train resistors<\/a><\/li>\n<li id=\"menu-item-10124\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-10124\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/girdbox\/\">Gridbox<\/a><\/li>\n<li id=\"menu-item-8017\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8017\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/discover-oil-starter-now-gino-ag\/\">Oil-cooled resistor starters<\/a><\/li>\n<li id=\"menu-item-8006\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8006\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/akamas-gino-ag\/\">GINO-AKA AKAMAS<\/a><\/li>\n<li id=\"menu-item-8007\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8007\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/power-controller-gino-ag\/\">GINO-AKA power controllers<\/a><\/li>\n<li id=\"menu-item-8009\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8009\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/discover-liquid-starters-gino-ag\/\">Liquid cooled starters<\/a><\/li>\n<li id=\"menu-item-8016\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8016\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/discover-air-cooled-starter-gino-ag\/\">Air cooled motor starters<\/a><\/li>\n<li id=\"menu-item-8020\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8020\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/discover-surge-protection-gino-ag\/\">Surge suppressor<\/a><\/li>\n<li id=\"menu-item-8005\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8005\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/cooling-systems-gino-ag\/\">Fans \/ cooling systems<\/a><\/li>\n<li id=\"menu-item-7999\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-has-children menu-item-7999\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/electric-contactors-gino-ag\/\">Contactors<\/a>\n<ul class=\"sub-menu\">\n\t<li id=\"menu-item-8000\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8000\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/electric-contactors-gino-ag\/contactors-hb-series\/\">Contactors \u2013 HB series<\/a><\/li>\n\t<li id=\"menu-item-8003\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8003\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/electric-contactors-gino-ag\/contactors-t-series\/\">Contactors \u2013 T series<\/a><\/li>\n\t<li id=\"menu-item-8001\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8001\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/electric-contactors-gino-ag\/contactors-r-series\/\">Contactors \u2013 R series<\/a><\/li>\n\t<li id=\"menu-item-8002\" class=\"menu-item menu-item-type-post_type menu-item-object-page menu-item-8002\"><a href=\"https:\/\/www.gino-ag.com\/en\/products\/electric-contactors-gino-ag\/contactors-s-series\/\">Contactors \u2013 S-Series<\/a><\/li>\n<\/ul>\n<\/li>\n<\/ul><\/div><\/div><\/div><div id=\"panel-1130-0-1-1\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-last-child\" data-index=\"3\" ><div class=\"info-box panel-widget-style panel-widget-style-for-1130-0-1-1\" ><div class=\"textwidget\"><div class=\"info-box\">\n<h2>Contact person<\/h2>\n<p>Kevin Phillips<br \/>\nPhone: +49 (0) 228 98986-51<br \/>\nEmail: <a href=\"mailto:kevin.phillips@gino.de\">kevin.phillips@gino.de<\/a><\/p>\n<p>Anton Daryevych<br \/>\nTelefon: +49 (0) 228 98986-47 <br \/>\nE-Mail: <a href=\"mailto:anton.daryevych@gino.de\">anton.daryevych@gino.de<\/a><\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li><a href=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/Imagebrochure-Gino_AG.pdf\" target=\"_blank\" rel=\"noopener\">Image brochure<\/a> (PDF)<\/li>\n<\/ul>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Starting resistors are used to start large three-phase asynchronous machines with slip-ring rotor. The starting resistor is started in the rotor circuit and switched off stepwise. It limits the starting current of the motor and increases its effective component (rating factor) and thus the drive torque because only the effective component is decisive for the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":5708,"parent":954,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-1130","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.1.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Starting resistors - GINO AG<\/title>\n<meta name=\"description\" content=\"Starting resistors are used to start large three-phase asynchronous machines with slip-ring rotor.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Starting resistors - GINO AG\" \/>\n<meta property=\"og:description\" content=\"Starting resistors are used to start large three-phase asynchronous machines with slip-ring rotor.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/\" \/>\n<meta property=\"og:site_name\" content=\"GINO AG\" \/>\n<meta property=\"article:modified_time\" content=\"2022-01-20T17:22:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Header_Produkte.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"480\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/\",\"url\":\"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/\",\"name\":\"Starting resistors - GINO AG\",\"isPartOf\":{\"@id\":\"https:\/\/www.gino-ag.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Header_Produkte.jpg\",\"datePublished\":\"2016-06-20T13:53:12+00:00\",\"dateModified\":\"2022-01-20T17:22:35+00:00\",\"description\":\"Starting resistors are used to start large three-phase asynchronous machines with slip-ring rotor.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/#primaryimage\",\"url\":\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Header_Produkte.jpg\",\"contentUrl\":\"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Header_Produkte.jpg\",\"width\":1920,\"height\":480},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\/\/www.gino-ag.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/www.gino-ag.com\/en\/products\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Starting resistors\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gino-ag.com\/en\/#website\",\"url\":\"https:\/\/www.gino-ag.com\/en\/\",\"name\":\"GINO AG\",\"description\":\"Elektrische Widerst\u00e4nde von 50 W bis 360 MW\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gino-ag.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Starting resistors - GINO AG","description":"Starting resistors are used to start large three-phase asynchronous machines with slip-ring rotor.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/","og_locale":"en_US","og_type":"article","og_title":"Starting resistors - GINO AG","og_description":"Starting resistors are used to start large three-phase asynchronous machines with slip-ring rotor.","og_url":"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/","og_site_name":"GINO AG","article_modified_time":"2022-01-20T17:22:35+00:00","og_image":[{"width":1920,"height":480,"url":"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Header_Produkte.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/","url":"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/","name":"Starting resistors - GINO AG","isPartOf":{"@id":"https:\/\/www.gino-ag.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/#primaryimage"},"image":{"@id":"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/#primaryimage"},"thumbnailUrl":"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Header_Produkte.jpg","datePublished":"2016-06-20T13:53:12+00:00","dateModified":"2022-01-20T17:22:35+00:00","description":"Starting resistors are used to start large three-phase asynchronous machines with slip-ring rotor.","breadcrumb":{"@id":"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/#primaryimage","url":"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Header_Produkte.jpg","contentUrl":"https:\/\/www.gino-ag.com\/wp-content\/uploads\/GINO_Header_Produkte.jpg","width":1920,"height":480},{"@type":"BreadcrumbList","@id":"https:\/\/www.gino-ag.com\/en\/products\/starting-resistors\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.gino-ag.com\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.gino-ag.com\/en\/products\/"},{"@type":"ListItem","position":3,"name":"Starting resistors"}]},{"@type":"WebSite","@id":"https:\/\/www.gino-ag.com\/en\/#website","url":"https:\/\/www.gino-ag.com\/en\/","name":"GINO AG","description":"Elektrische Widerst\u00e4nde von 50 W bis 360 MW","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gino-ag.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.gino-ag.com\/en\/wp-json\/wp\/v2\/pages\/1130","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.gino-ag.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.gino-ag.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.gino-ag.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gino-ag.com\/en\/wp-json\/wp\/v2\/comments?post=1130"}],"version-history":[{"count":5,"href":"https:\/\/www.gino-ag.com\/en\/wp-json\/wp\/v2\/pages\/1130\/revisions"}],"predecessor-version":[{"id":8464,"href":"https:\/\/www.gino-ag.com\/en\/wp-json\/wp\/v2\/pages\/1130\/revisions\/8464"}],"up":[{"embeddable":true,"href":"https:\/\/www.gino-ag.com\/en\/wp-json\/wp\/v2\/pages\/954"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.gino-ag.com\/en\/wp-json\/wp\/v2\/media\/5708"}],"wp:attachment":[{"href":"https:\/\/www.gino-ag.com\/en\/wp-json\/wp\/v2\/media?parent=1130"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}